Case study
Other sectors
Issue
Developing a system of protection resistant to continuous magnetic fields of at least 4800 A/m
Methods
3D finite element modelling (FEM), laboratory tests
Results
Integration of a MuMetal cage with adjustable geometry, not occupying additional space, resistant in accordance with the test protocol described in the ISO 764 standard. Tested by an accredited laboratory.